sourceP.U.C.O. No. 17: D19 Secondary (34th Revised), riders D27-D41 at their Secondary rates, T8 TCRR and G10, with D2 (139th Revised) as the revision index
verifiedTranscribed from the utility's filed sheetP.U.C.O. No. 17: D19 Secondary (34th Revised), riders D27-D41 at their Secondary rates, T8 TCRR and G10, with D2 (139th Revised) as the revision index
verifiedEffective date on the sheet: 2026-11-01
verifiedReconciles to a total the utility published itselfNOT RECONCILED. Every value is transcribed from its current filed sheet. AES's posted commercial bill calculator is dated 6-1-2025 and no commercial Price to Compare was found.
verifiedSource document checked daily for changes
approximateThis is not a whole billdelivery and default supply — delivery plus the utility's default supply; a customer who buys supply elsewhere pays the delivery part only
excludedTaxes, franchise fees and local surchargesJurisdiction-specific, so they are deliberately not encoded. A bill will be higher than this figure by that amount.
Energy rates
Period
Applies to
$/kWh
Other plans at this utility
Encoded from the same tariff book, on the same day. Which one
you are on is on your bill; which one you are eligible for is set by the
utility, not by this page.
Transcription notes recorded when this tariff was encoded, including anything deliberately left out.
NO DISTRIBUTION ENERGY CHARGE: D19 bills the customer charge and $7.80 per kW, and the three percentage riders are a percentage of those two.
TRANSMISSION (T8) IS NON-BYPASSABLE and largely per kW; a shopping customer still pays it. shopping=True drops only G10.
BILLING DEMAND: on-peak demand, 75% of off-peak demand, or 75% of the highest Jun-Aug / Dec-Feb billing demand in the past eleven months (pass that as highest_previous_demand_kw).
Think a figure here is wrong?
Email support@rategrid.dev
with this plan's name and what the filed sheet says. Every rate on this page was
transcribed from the document linked above, so a report that quotes the sheet can
be checked against it and corrected.
Change history
The source document is fetched daily and every version is kept.
Utilities do not publish superseded rates, so this record does not exist
elsewhere once a rate changes.
No changes detected since monitoring began. The source sheet is checked daily.